FILTER*Select the corresponding category and view the product

Star-Delta Starters
Select
SMC AC Contactor
Miniature Circuit Breaker (MCB)
SMSE
AOV2
QJX2
SAU Aux.Contacts Blocks
Single Function
AGK / AGKM
Mini Molded Case Circuit Breaker (Mini MCCB)
CJX2 AC Contactor 3-Pole
Time Relay
SMS
Phase Failure Protection Relay
CJX2 AC Contactor 4-Pole
Digital Display
AOV3
QJX3
SAC Capacitor Unit
Mini Earth Leakage Circuit Breaker (Mini ELCB)
DC Miniature Circuit Breaker (DC MCB)
SMC Large Capacity Contactor
AFKV-NH/NHF/HF (Digital Display)
SMC-C Capacitor Contactor
CJX2-N Reversing Contactor
Molded Case Circuit Breaker (MCCB)
ADGK (Digital Display)
Voltage Protection Relay
Double Delay
SAR Mechanical Interlock Unit
Residual Current Circuit Breaker
CJX2-Z DC Contactor
SMC-Z DC Contactor
Surge Protective Device (SPD)
Earth Leakage Circuit Breaker (ELCB)
Multifunction
SAZ Separate Mounting Base
AFKD/ADFK (Digital Display)
Over Current Protection Relay
CJ19 Capacitor Contactor
SMC-N Reversing Contactor
F8/F4 Aux. Contacts Blocks
DC Molded Case Circuit Breaker (DC MCCB)
DC Surge Protective Device (DC SPD)
PV Fuse
Phase Protection Relay
Miniature Switch Disconnecter (MSD)
JR28 Thermal Overload Relay
CJ19 Switchover Capacitor Unit
PV Connector
MR Contactor Relay
Under Voltage Protection Relay
Modular Contactors
Contactor Relay
LA2/LA3 Air Timer Delay
PV Combiner Box
Special Electronic Contactor
SMR Thermal Overload Relay
Consumer Unit
LA9 Mechanical Interlock Unit
D.O.L Motor Starter
Motor Circuit Breaker
Level Control Relays
SAZ1 Separate Mounting Base
SMS D.O.L Motor Starter
CJX2N-D AC Contactor
AORD Over Current Protection Relay
AOCR-SS
AOV2 Shunt Release/ Upper Auxiliary
AOR2 Thermal Overload Relay
AOCR-AR
AOV2 Waterproof Mounting Box
AOCR-SSD
Star-Delta Starters
AUCR
AOCR-SE2
Moulded Case Circuit Breaker
AOUE Type 1+2
Earth Leakage Circuit Breaker
AOX1-□M/HLN
AOUE Type 2
AOCT-M Manual Operation
Moulded Case DC Circuit Breaker
AOCT Electric Operation
Circuit Breaker for Specific Purpose
AOUE Type 2+3
AOX1-□M/L
AOX1-□M/HL
Circuit Breaker
PM-12
Three-Phase Distribution Box
AOX1-□M/HLB
AOX1-□M
Circuit Breaker Accessories
Ammeter
MSD is given priority to switch the consumer units
MSD is given priority to switch and RCD division unit load consumer
MSD is given priority to switch and RCD division 2 load consumer units
RCD is given priority to switch the consumer units
2 RCD is given priority to switch the consumer units
2 MSD is given priority to switch the consumer units
MSD is given priority to switch and SPD division unit load consumer
AOU Acoustic and Visualin Dicator
ASR
PR-30/DRP-6D
QCX2
Voltmeter
Frequency Meter
Multimeter
AOS
SMC-P2
SMC-D2/D3
Contactor Aux.Contacts Blocks
SAU Aux.Contacts Blocks
Contactor Capacitor Unit
SAC Capacitor Unit
Contactor Mechanical Interlock Unit
SAR Mechanical Interlock Unit
Thermal Relay Separate Mounting Base
SAZ Separate Mounting Base
Contactor Air Timer Delay
Motor Circuit Breaker Waterproof Mounting Box
Motor Circuit Breaker Shunt Release/ Upper Auxiliary
AOLE
AOLR
AVSR
SMC Contactor Accessories
DIN Rail Electric Meter
Pointer Type Electric Meter
Mutual Inductor
AORD
ATRM (Digital Display)
Overvoltage and Undervoltage Protection Relay
Products
SMC Contactor and Protection Relay
Distribution Electrical Appliances
Time and Protection Relay
Electrical Measuring Instruments
Terminal Electrical Appliances
Motor Control and Protection

QJX2-80/95 Star-Delta Starter

Star-Delta Starters

Characteristics

QJX2 Series star-delta reduced voltage starter is suitable for starting motor in the circuit of AC 50/60Hz, voltage up to 380V and current up to 95A. It is a motor starter which provided with timer for automatic changeover of star-delta to reduce the voltage and current of motor starting.

Notice:Please note enclosed or open type when placing order.


Normal working conditions and installation conditions:

Temperature: -5°C ~ +40°C, average temperature not exceed +35°C in 24 hours.

Altitude: Do not exceed 2000m.

Air Condition: Atmospheric relative humidity can’t exceed 50% at ambient air temperature of +40℃,and the higher relative humidity may be allowed at lower temperatures. For example, when the ambient air degree is 20℃, the relative humidity can reach 90%. Because of the occasional condensation

phenomenon of the product due to the temperature changes, the user should take special protective measures.

Pollution Grade:  Grade 3.

Installation category:III Class.

Mounting Condition: The inclination between the mounting plane and the vertical plane shall not exceed ±5°.

Impact shock: The product shall be installed and operated at a place without obvious shake, impact and vibration.


Main parameter and technical characteristic:

Model

Rated Insulated Voltage Ui (V)

Ie under

Intermittent Duty (A)

Max. Power of Motor

can be controlled(kW)

Thermal Overload Relay

Model Specification of AC contactor

380V

660V

220V

380V

660V

Type


Setting Current
 Range


Y Operate KM1

Operate KM3

Isolation

with KM2

QJX2-09

690

09

09

4

7.5

10

JR28-13

7-10

CJX2-0910

CJX2-0901

CJX2-0910

QJX2-12

12

8.9

5.5

11

13

JR28-13

9-13

CJX2-0910

CJX2-1201

CJX2-1210

QJX2-18

18

10.6

7.5

15

18.5

JR28-13

12-18

CJX2-1210

CJX2-1801

CJX2-1810

QJX2-25

25

18

11

18.5

25

JR28-13

17-25

CJX2-1810

CJX2-2501

CJX2-2510

QJX2-32

32

21

15

25

33

JR28-13

23-32

CJX2-1810

CJX2-3201

CJX2-3210

QJX2-40

40

34

18.5

33

50

JR28-33

30-40

CJX2-2510

CJX2-4011

CJX2-4011

QJX2-50

50

39

25

45

63

JR28-33

37-50

CJX2-4011

CJX2-5011

CJX2-5011

QJX2-65

65

42

30

55

63

JR28-33

48-65

CJX2-4011

CJX2-6511

CJX2-6511

QJX2-80

80

49

37

63

80

JR28-33

63-80

CJX2-5011

CJX2-8011

CJX2-8011

QJX2-95

95

49

45

80

80

JR28-33

80-93

CJX2-6511

CJX2-9511

CJX2-9511


Outline and installation dimension:

QJX2-40~95 Open type:


Model

QJX2-40

QJX2-50

QJX2-65

QJX2-80

QJX2-95

A

310

310

310

310

310

C

185

185

185

196

196


QJX2-40~95 Enclosed type:


Model

QJX2-40

QJX2-50

QJX2-65

QJX2-80

QJX2-95

A

470

B

265

C

110

If you have any enquiry about quotation or cooperation,please feel free to email us ator use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.