FILTER*Select the corresponding category and view the product

Select
Select
Mini Contactors
SMC-Z
SMC-C
SMC-N
Time Relays
SMR
Miniature Circuit Breaker (MCB)
Molded Case Circuit Breaker (MCCB)
SMSE
AOV2
QJX2
SAU Aux.Contacts Blocks
DC MCCB
AERV Single Function
AGK
ATS
AMC
SMM
SMC
AC Contactors
SMS
Phase Protection Relays
Earth Leakage Circuit Breaker (ELCB)
AERV-09 Double Delay Time Relay
AOV3
QJX3
SAC Capacitor Unit
Residual Current Circuit Breaker (RCCB)
ATSD
DC MCB
CJX2-N
CJX2-Z
CJ19
CJX2N-D
Thermomagnetic Adjustable
4P AC Contactors
Voltage Control Relays
JR28
ADRV Digital Timer
AOR2
SAR Mechanical Interlock Unit
Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
DC Contactor
Reversing Contactors
Electronic Liquid Crystal
Level Control Relays
AERX Multifunction
SAZ Separate Mounting Base
Residual Current Device (RCD)
DC SPD
CJX2
DC Contactors
Miniature Switch Disconnecter (MSD)
Intelligent Electronic Adjustable
Wire Contact Relays
F8/F4 Aux. Contacts Blocks
PV Fuse
Surge Protective Device (SPD)
Thermal Overload Alarm Does not Operate
AFK
CJ19 Switchover Capacitor Unit
ADS18 Single Phase Energy Meter
Waterproof Distribution Box
PV Connector
Time Switch
Modular Contactors
Capacitor Contactors
ADGK Digital Display
LA2/LA3 Air Timer Delay
Single Phase Smart Switch
Mini Molded Case Circuit Breaker (Mini MCCB)
PV Combiner Box
Consumer Unit
Thermal Overload Relays
LA9 Mechanical Interlock Unit
ADS36 Single Phase Energy Meter
Mini Earth Leakage Circuit Breaker (Mini ELCB)
Electronic Over Current Relays
SAZ1 Separate Mounting Base
Single Phase Protective Energy Meter
AOCR-SS
AOV2 Shunt Release/ Upper Auxiliary
Single Phase WIFI Smart Switch
Contactor Relays
AOCR-AR
AOV2 Waterproof Mounting Box
ADS76 Single Phase Energy Meter
Motor Circuit Breakers
Three Phase Energy Meter
AOCR-SSD
D.O.L Motor Starters
Star-Delta Starters
AUCR
AOCR-SE2
Moulded Case Circuit Breaker
AOX1-□M/H
AOUE Type 1+2
Earth Leakage Circuit Breaker
AOX1-□M/HLN
AOUE Type 2
AOCT-M Manual Operation
Moulded Case DC Circuit Breaker
AOCT Electric Operation
Circuit Breaker for Specific Purpose
AOR9-F
AOUE Type 2+3
AOX1-□M/L
AOX1-□M/HL
Circuit Breaker
AOMD
PM-12
Three-Phase Distribution Box
AOX1-□M/HLB
AOX1-□M
Circuit Breaker Accessories
Ammeter
MSD is given priority to switch the consumer units
MSD is given priority to switch and RCD division unit load consumer
MSD is given priority to switch and RCD division 2 load consumer units
RCD is given priority to switch the consumer units
2 RCD is given priority to switch the consumer units
2 MSD is given priority to switch the consumer units
MSD is given priority to switch and SPD division unit load consumer
AOX1-□M/HLR
AOX1-□M/HLR-2
AOX1-□M/LR
AOX1-□M/LR-2
AOX1-□M/H-2
AOX1-□M/HU
AOU Acoustic and Visualin Dicator
AON
AON1
AOH-100
AOH-125
AFKD/ADFK Digital Display
ASR
PR-30/DRP-6D
ADS18-D
ADS18-ZN Multi-Function
ADS18-WIFI
ADS18-Zigbee
ADS18-W WIFI
ADS18-Z Zigbee
ADS36-WIFI
ADS36-D
ADS36-Zigbee
ADS36-ZN Multi-Function
ADS36-VAP/1 Voltage/ Current
ADS36-VAP/2 Water Pump
ADS36-VAP/3 Voltage/ Current/ Temperature
MCB36
MCB36-E Metering Module
ADS76-D
ADS76
ADS76-W RS485
ADS76-W/SR WIFI
ATS76-D
ATS76-ZN Multi-Function
ATS126-D
ATS126-ZN Multi-Function
ATS126-W RS485
ATS126-WIFI
ATS126-VAP Voltage/ Current
Accessories
QCX2
Voltmeter
Frequency Meter
Multimeter
AOS
Products
Relay and Controller
Control and Protection Products
Power Meter
Terminal Electrical Appliances
Distribution Electrical Appliances
New Energy DC Products

ADR-45W

ADR

Characteristics

ADR series is a 30~480W single-group output closed power supply with 85-264VAC full range AC input. The entire series is available in 5V,12V,15V,24V,36V and 48V outputs.
In addition to an efficiency of up to 91.5%, the metal mesh housing design enhances heat dissipation so that ADR-30,45,60 operate in the temperature range of -30℃ to +70℃ without a fan . It makes it easy for terminal systems to meet international energy requirements. ADR series has a complete protection function, it complies with TUV EN60950-1,EN60335-1,EN61558-1/-2-16,UL60950-1 and GB4943 international safety regulations, The ADR series provide a cost-effective solution for a variety of industrial applications.

ADR-30  30W Rail type switch power supply:

Type ADR-30 ADR-45 ADR-60
Meet a cirterion TUV EN60950,EN61558-1/-2-16,UL60950-1,GB4943
 Output  DC voltage(V) 5V、12V、15V、24V
 Rated current(A) 3A、2A、2A、1.5A 5A、3.5A、2.8A、2A 6.5A、4.5A、4A、2.5A
 Rated power(W) 15W、24W、30W、36W 25W、42W、42W、48W 32.5W、54W、60W、60W
 Ripple swept noise <80mV、<120mV、<120mV、<150mV
 Voltage regulation range ±10%
 Voltage accuracy 5V ±2% 12~24V ±1%
 Linear adjustment rate <±1%
 Load regulation ±1%
 Hold time 100ms、30ms:110VAC 100ms、30ms:220VAC
 Input  Start, rise time 21ms:110VAC 100ms:220VAC
 Efficiency (typical) >78%、>81%、>83%、>84%
 Working current <0.8A 110VAC <0.4A 220VAC 0.8A 110VAC <0.4A 220VAC <1.2A 110VAC <0.8A 220VAC
 Surge current 110VAC 18A  220VAC 36A
 Protect  Overload protection ≥105%-150%
 Short circuit protection  +VO down to the undervoltage point to close the output
 Environmental  Operating temperature and humidity -10℃~+50℃; 20%~90RH
 Storage temperature and humidity -20℃~+85℃; 10%~95RH
 Safety standard  Withstand voltage Input-output:3KVAC
 Isolation resistance Input-output, (enclosure):500VDC/100MΩ
 Other  Size(mm) 79*93*56( L*W*H)
 Net Weight/Gross weight 270g/290g

If you have any enquiry about quotation or cooperation,please feel free to email us ator use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.